Alert 98 – 14 Bolt Breakage

WHAT HAPPENED:

While pulling out of the hole, both brake band anchor bolts failed. The elevators were about six feet (two meters) above the rotary table. Descent of the top drive system and traveling block was controlled using the brake and low clutch. No personnel were injured.